High Frequency Transformers Ferrite Core Range |
The selection of the ferrite core type for a specific transformer depends on the design parameters and the designer’s personal preferences. The indicative power capacity for different core types (chart below) provides a general guideline for an initial core selection. We hold UL insulation system for Class B(130℃),F(155℃),H(180℃). We can make customized lamination transformers.
Power Capacity Chart
|
|
Power range (W)
|
Core type using N67* grade material
|
<5
|
RM4; P11/7; EF12.6; U10
|
5-10
|
E(F)16; RM5; P14/8
|
10-20
|
RM6; E(F)20; P18; U15; EFD15
|
20-50
|
RM8; P22; RM10 ETD29; E25; EFD20
|
50-100
|
ETD29; ETD34; RM12; P30; EFD25
|
100-200
|
ETD34; ETD39; ETD44; P36; E30; E42; EFD30
|
200-500
|
ETD44; ETD49; E55
|
>500
|
ETD54; ETD59; E65
|
Note: The power capacity of each core type varies due to differences in topology, operating frequency and temperature, flux density, and material grade.